Search results for "Cell density"
showing 10 items of 20 documents
Toxicity and cell density monitoring in monolayer and three-dimensional cultures with the XTT assay
1998
The application of viability criteria (MTT and XTT tests) to monolayer cultures and immobilised cells in three-dimensional systems was investigated in order to assess cell viability and cell proliferation. The suitability and accuracy of these tests were compared with the conventional criteria (cellular protein and DNA content) used in monolayer cultures for the same purpose. The colorimetric assay based on the metabolic reduction of the tetrazolium salt XTT to a water-soluble formazan proved to be very useful, rapid and sensitive. This automated spectrophotometric enzymatic method, due to its lack of toxicity, also permits repeated nondestructive assays on a single cellular culture for the…
How to Predict the Suitability for Corneal Donorship?
2021
Background: In Germany, more than one-third of donor corneas harvested are not suitable for transplantation. We evaluated the factors associated with the usability of donor corneas. Method: Data from 2032 consecutive donor corneas harvested at the Rhineland-Palatinate Eye Bank in Mainz, Germany, were retrospectively analyzed. Factors of interest were age, sex, lens status, cause of death, cardiopulmonary resuscitation (CPR), death-to-explantation-interval (DEI), and the influence of these factors on the proportion of discarded donor corneas. Factors associated with endothelial cell density (ECD) were analyzed in a linear regression mixed model. Results: Higher donor age, male gender, pseudo…
Histological and morphometric study of the components of the sinus and atrioventricular nodes in horses and dogs
2019
Abstract The cardiac nodes are the source of the electrical impulse that is transmitted to the heart, the aim of this work is study the histological and morphometric characteristics of the different components of the sinus and atrioventricular nodes in horses and dogs that help to know the physiopathology of these nodes. A group of ten horse hearts and five dog hearts were used. The region of the sinus and atrioventricular nodes was sectioned serially, and the block of tissue removed for study. The samples were assessed using a morphometric analysis with the Image-Pro Plus 7.1 software and the acquisition of the images using a Leica DMD108 optic microscope. The shape of the horse's sinus no…
Comparison of DMEK and DSAEK in Eyes With Endothelial Decompensation After Previous Penetrating Keratoplasty.
2021
PURPOSE Posterior lamellar keratoplasty is increasingly applied in patients with endothelial decompensation after penetrating keratoplasty (PK). The aim of this study was to compare the results of Descemet membrane endothelial keratoplasty (DMEK) and Descemet stripping automated endothelial keratoplasty (DSAEK) after PK. METHODS In this retrospective study, clinical data of 30 patients who received DMEK (n = 19) or DSAEK (n = 11) for endothelial decompensation after PK were evaluated. All lamellar keratoplasties were performed at the Department of Ophthalmology at University Hospital Mainz, Germany. Primary end point included best-corrected visual acuity, and secondary end points included e…
Differences in Corneal Anatomy in a Pair of Monozygotic Twins Due to Continuous Contact Lens Wear
2003
Purpose To study the differences in the corneal anatomy in a pair of 31-year-old monozygotic female twins, one of whom has been a contact lens wearer for the past 15 years and the other is a nonwearer. Methods We analyzed the corneal thickness and the corneal endothelial cell density of the monozygotic twins and of two age-matched control groups, one made up of non-contact lens wearers (35 eyes of 35 patients; mean age, 29.32 +/- 2.83 years) and the other made up of soft contact lens wearers (30 eyes of 30 patients; mean age, 33.08 +/- 3.72 years; mean duration of contact lens use, 10.62 +/- 4.32 years). Five corneal thickness measurements were carried out with the Orbscan Topography System…
Collagen copolymer posterior chamber phakic intraocular lens for hyperopia correction: three-year follow-up.
2013
Purpose To assess the efficacy, predictability, safety, and stability of the Visian V3 Implantable Collamer Lens posterior chamber phakic intraocular lens (PC pIOL) for moderate to high hyperopia. Setting Private clinic, Oviedo, Spain. Design Prospective nonrandomized clinical study. Methods The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, endothelial cell density, intraocular pressure (IOP), central vault, and adverse events were evaluated for 3 years postoperatively. Results The study comprised 73 eyes of 44 patients. The mean spherical equivalent decreased from +4.84 diopters (D) ± 1.6 (SD) (range +1.00 to +7.75 D) preoperatively to −0.13 ± 0.39 …
Granulometric analysis of corneal endothelium specular images by using a germ–grain model
2007
Specular microscopy is widely used to study the human corneal endothelium status in vivo. In this paper, the corneal endothelium is represented as a binary image composed of the cell inscribed circles. The granulometric distribution function of the complement of this image is used as a functional descriptor, which provides information about the shape, size and spatial arrangement of cells. Experimental evaluation using bootstrap techniques shows its ability to discriminate between controls and pathological cases. It represents a reliable and graphical alternative to the classical indices (cell density, hexagonality and coefficient of variation of cell areas), which behave poorly when detect…
MORPHOMETRIC ANALYSIS OF HUMAN CORNEAL ENDOTHELIUM BY MEANS OF SPATIAL POINT PATTERNS
2002
This paper presents a method for detecting abnormalities in spatial arrangements of cells within any tissue that can be described by different sets of relevant points. The method has been applied to the detection of subtle abnormalities in corneal endothelia. Images of this type of tissue can be characterized by two types of points: cell centroids and triple points associated with the apical intersections as it was proposed by Díaz.7 Both types of points jointly considered are modeled using a bivariate spatial point process; then a statistical analysis based on certain distributional descriptors proposed by Doguwa4,9 is carried out to discriminate severe and subtle abnormalities from contr…
Classifying human endothelial cells based on individual granulometric size distributions
2002
Abstract This paper presents an application to a medical problem of methods of shape analysis based on mathematical morphology. The medical problem consists on the detection of abnormalities in the corneal endothelium, a tissue composed by quasi-planar cells of ideally regular hexagonal shape. Images of this tissue are taken by a specular microscope and used to evaluate the corneal endothelium status. Up to now, cell density, hexagonality and an analysis of cell areas are the usual descriptors of a corneal endothelium. These parameters are not sensitive enough to detect subtle lesions. What this paper proposes is an analysis based on granulometries, which are size-shape descriptors widely u…
Set Descriptors for Visual Evaluation of Human Corneal Endothelia
2001
Images of corneal endothelium obtained from specular microscopy are of great importance in the evaluation of the corneal endothelium status. Several commercial tools provide some numerical descriptors to characterize these images in terms of cell density, hexagonality, and some descriptive statistics of the cell areas. However, it is a too simple analysis that only detects severe abnormal endothelia with many irregular and large cells. Detection of subtle abnormalities needs a more refined analysis. This paper proposes a shape-size descriptor based on some modified versions of the geometric covariogram. This descriptor is presented as a valid alternative to the classical analysis that provi…